IEC 62271-107:2012

Title
Abstract

IEC 62271-107:2012 applies to three-pole operated units for distribution systems that are functional assemblies of a circuit-switcher and current-limiting fuses designed so as to be capable of:
- breaking, at the rated recovery voltage, any load or fault current up to and including the rated short-circuit breaking current;
- making, at the rated voltage, circuits to which the rated short-circuit breaking current applies. This second edition cancels and replaces the first edition, published in 2005. It constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition.
- the reference to IEC 60694 has been changed to IEC 62271-1;
- the new clauses and subclauses from IEC 62271-1 have been added and where necessary new wording has been provided;
- the normative references have been updated: IEC 60265-1 to IEC 62271-103, IEC 60787 to IEC/TR 60787, IEC 60466 to IEC 62271-201, and IEC/TR 60787 was moved to the bibliography;
- the figures and tables have been placed in the document where they are first cited;
- the numbering of figures and tables has been changed to obtain the correct order;
- the definition of NSDD was deleted. This definition is included in IEC 62271-1;
- the acceptance criteria have been aligned with 6.101.4 of IEC 62271-103:2011;
- the various provisions expressed about "extension of the validity of type tests" have been grouped under 6.103: some of the rules were duplicated in Clauses 6 and 8, and it seems better fitted to deal within each type test sub-clause only with the type test to be performed. Conditions have not been changed, but the wording is clearer;
- new numbering of subclauses in Clauses 8 and 9 to avoid conflict with clauses from IEC 62271-1.

This publication is to be read in conjunction with IEC 62271-1:2007.

Issue Date

2012-05-29

Category

POW

Included in IECEE System

2014-02-19

Purchase webstore
Test Report Form
Testing Equipment List
DISCLAIMER: National differences

The National differences and Group differences, National Deviations and Special National conditions (SNC), are based solely on information provided to the Secretariat by the IECEE Member Bodies and/or NCBs and other sources. The IEC/IECEE is not responsible for, nor will it take any position related to, the accuracy or validity of the information provided. To verify the current status of this type of information, we recommend contacting the Member Body (MB) or National Certification Body (NCB) of the relevant country.

Group Differences are applicable for CENELEC member countries: Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.

No information declared

Laboratory Name

City

Country

Responsible National Certification Body

Shaanxi

China

Id

Name

City

Country

13349

Budapest

Hungary

No information declared